DB-CPLD-PL BOARD
The Testing and Programming Board DB-CPLD-PL is determined for
programming and testing all XILINX XC9500 family devices in PLCC44
and PLCC84 packages in co-operation with XILINX development software
Foundation or Alliance. Board can be connected to PC in two ways:
- connection to serial port using XChecker Cable
- connection to parallel port using Parallel Cable III (delivered
with development systems)
Power supply
Tested devices can be inserted together in two sockets in the same
time.
There are four power supply options :
 |
 |
|
Power supply
|
Connection
|
Jumper J10
|
Jumper "short"
|
Notes
|
|
stabilised 5V
|
connector ARK120/3
|
connected pins2 and 3
|
disconnected
|
standard
|
|
stabilised 5V and 3,3V
|
connector ARK120/3
|
disconnected pins 2 and 3
|
disconnected
|
compatibility I/O drivers with
3,3V supply voltage
|
|
unstabilised up to 20V
|
connector K1-JACK 3,5mm(plus pole
in the middle)
|
connected pins2 and 3
|
connected
|
|
|
unstabilised up to 20Vand 3,3V
power supply
|
connector K1-JACK 3,5mm+ connector
ARK120/3
|
disconnected pins 2 and 3
|
connected
|
compatibility I/O drivers with
3,3V supply voltage
|
|
 |
 |
Possibility of usage:
- erasing and checking ERASE, BLANK CHECK
- programming and checking PROGRAM, VERIFY
- device type identification check DEVICE ID
- device user signature check USER SIGNATURE
- programming of the read and write permission SECURITY BIT ,
READ, WRITE
General information
DB-CPLD-PL board for XILINX XC9500 family devices is product of
ASICentrum company. Any copying and production without written ASICentrum’s
authorization is strictly prohibited.
|